Product Details:
|
Encapsulation: | Aluminum | Product Name: | LaCl3 Scintillator DMCA Detector |
---|---|---|---|
DMCA: | Available | Configuration: | PMT |
Advantage: | High Counting Rate,good Energy Resolution,high Light Output | Materail: | LaCl3 Scintillator, LaCl3 Crystal |
Size: | 1"x1";1.5"x1.5";2"x2" | Work Temperature: | 0℃ ~ +40 |
Storage Temperature: | -20 ~ 55 | ||
High Light: | LaCl3 Scintillator Detector,PMT scintillation crystal,2"x2" Scintillator Detector |
Excellent energy resolution environmental monitoring LaCl3 Scintillator Detector
LaCl3(Ce) | Scintillation Crystal is a new generation of nuclear radiation detection materials. It has high energy resolution and time resolution, good energy non-linearity, and fast decay time. Its light yield is equivalent to NaI:Tl crystal, and the decay time is 1/10 of NaI:Tl. The energy resolution is 1/2~1/3 times of NaI:Tl and it also has good mechanical properties. Additionally, LaCl3(Ce) crystal has good temperature properties and a wide temperature range with good energy resolution consistency.
Performance of a LaCl3(Ce) scintillator for application in environmental gamma-ray dosimetry and spectrometry has been studied over a wide range of dose rates. The results of our experiments reflect its excellent physical properties, affording better energy resolution and faster response than NaI(Tl). A LaCl3(Ce) scintillator favorably replaces the NaI(Tl) scintillator in the environmental monitoring, especially under emergency situation.
Properties:
Specification | Range | Unit |
Scintillator Effective Size | φ25 X 25 | mm |
Input Voltage | 11.5 ~12.5 | V |
Input Current | ≤60 | mA |
Output Polarity | Positive Polarity | - |
Output Amplitude (MAX)1) | 9 | V |
Output Amplitude(TYPE)2) | 1 | V |
Resolution(Cs137)3) | ≤4.5 | % |
<span color:black;background:white;"="" style="font-size: 1pt;"> Background Count Rate(30kev~3Mkev) | ≤250 | min-1 |
Work Temperature | 0℃ ~ +40 | ℃ |
Storage Temperature | -20 ~ 55 | ℃ |
Humidity | ≤90 | % |
Notes:
1.Detector signal exceeds this value, a truncation will occur.
2.The amplitude of signal is usually less than 1V in spectrum analysis.
3.The value is measured when detector preheated for 10 minutes, the counting rate within 1000, total counting number is less than 105 in Cs137 peak.
Advantage:
Good energy resolution
High light output
High counting rate
Application:
Environmental monitoring
Oil well logging
Nuclear medicine
Nuclear medicine Security
Anti-terrorist
Nuclide identification
Product shots: