Home ProductsScintillator Detector

LaCl3 Scintillation Detector Optical Outputs With Good Linearity

Certification
China Kinheng Crystal Material (Shanghai) Co., Ltd. certification
I'm Online Chat Now

LaCl3 Scintillation Detector Optical Outputs With Good Linearity

LaCl3 Scintillation Detector Optical Outputs With Good Linearity
LaCl3 Scintillation Detector Optical Outputs With Good Linearity

Large Image :  LaCl3 Scintillation Detector Optical Outputs With Good Linearity

Product Details:
Place of Origin: China
Brand Name: Kinheng
Certification: ISO
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: Negotiable
Packaging Details: foam box
Delivery Time: 4-6 weeks
Payment Terms: T/T, Paypal
Supply Ability: 10000pcs/year

LaCl3 Scintillation Detector Optical Outputs With Good Linearity

Description
Encapsulation: Aluminum Product Name: LaCl3 Scintillator DMCA Detector
DMCA: Available Configuration: PMT
Advantage: High Counting Rate,good Energy Resolution,high Light Output Size: 1"x1";1.5"x1.5";2"x2"
Work Temperature: 0℃ ~ +40 Storage Temperature: -20 ~ 55
Product Material: Cerium-doped LaCl3(Ce) Crystal Fast Decay Time: Yes
High Light:

LaCl3 Scintillation Detector

,

Scintillator DMCA Detector

,

PMT Scintillation Detector

Optical outputs with good linearity LaCl3 Scintillator Detector

 

A new cerium-doped LaCl3(Ce) scintillator is evaluated with respect to the application in environmental gamma ray dosimetry and spectrometry. The scintillator is very attractive for gamma ray spectrometry in the case of high count rate, because it has excellent energy resolution and fast decay time.


Properties:

Specification Range Unit
Scintillator Effective Size φ25 X 25 mm
Input Voltage 11.5 ~12.5 V
Input Current ≤60 mA
Output Polarity Positive Polarity -
Output Amplitude (MAX)1) 9 V
Output Amplitude(TYPE)2) 1 V
Resolution(Cs137)3) ≤4.5 %
<span color:black;background:white;"="" style="font-size: 1pt;"> Background Count Rate(30kev~3Mkev) ≤250 min-1
Work Temperature 0℃ ~ +40
Storage Temperature -20 ~ 55
Humidity ≤90 %

Notes:
1.Detector signal exceeds this value, a truncation will occur.
2.The amplitude of signal is usually less than 1V in spectrum analysis.
3.The value is measured when detector preheated for 10 minutes, the counting rate within 1000, total counting number is less than 105 in Cs137 peak.

 

Advantage:

1.Good energy resolution

2.High light output

3.High counting rate

 

Application:

Environmental monitoring
Oil well logging
Nuclear medicine
Nuclear medicine Security
Anti-terrorist
Nuclide identification

 

Product shots:

LaCl3 Scintillation Detector Optical Outputs With Good Linearity 0

 

FAQ:

1.Q: Are you a factory manufacturer?

A: Yes ,we are manufacturer with 13 years experience in the scintillator crystal industry and supplied many famous brands with good quality and service.

 

2.Q:Where is your main market?

A:Europe, America, Asia.

 

Contact Details
Kinheng Crystal Material (Shanghai) Co., Ltd.

Contact Person: Ivan. wang

Tel: 18964119345

Send your inquiry directly to us (0 / 3000)