Product Details:
|
PMT Model No.: | CR173 CR160 CR119 XP3330 S600-8532 R1307 | Power Supply: | 5V 12V 19V 24V |
---|---|---|---|
Model: | MCA-X | Communication: | 485 |
Max Channel: | 32768 | Communication Rate: | 460800 |
Power Dissipation: | 3.5W | Applicable Temperature: | -20~ 55℃ |
High Light: | Digital Multi Channel Analyser,Nuclear Power Plant multichannel analyzer,Radiation Monitoring Multi Channel Analyser |
Nuclear power plant radiation monitoring Digital Multi Channel Analyser(MCA-X)
DMCA is a gamma spectroscopy acquisition module. It can be used for teaching and energy spectrum analysis. Kinheng Provide 2 types DMCA based on application.
MCA-X is an innovative product designed to operate as full-featured radiation detection systems for Gamma Spectroscopy and/or Neutron-Gamma Discrimination. Its profile makes this unit ideal for many portable applications where size, weight and power consumption are important constraints. Depending on the chosen model, the product is suitable for a wide range of applications.
Properties:
Type | MCA-1024 | MCA-2048 | MCA-X |
Applicable PMT | 2” OR Above | 2” OR Above | 2” OR Above |
PMT model No. | CR173 CR160 CR119 XP3330 S600-8532 R1307 | ||
Storage temperature | -40 ~ 70℃ | -40 ~ 70℃ | -40 ~ 70℃ |
Applicable temperature | -20~ 55℃ | ||
HV supply | 0~+1250V | ||
Scintillator | NaI(Tl)/ LaBr3 | ||
Humidity | ≤70% | ||
Power Supply | 5V | 5V | 5V 12V 19V 24V |
Spectrum stabilization | Applicable | ||
Communication | TTL | USB | 485 |
Max Channel | 1024 | 2048 | 32768 |
Power Protection | NOT | Anti static protection | Static |
Communication rate | 115200 | 460800 | 460800 |
Power dissipation | 1.4W | 1.8W | 3.5W |
Expansion board | Yes | No | No |
Property | Parameter |
Pulse pass rate | ≥ 1 million cps |
Number of channels | 1024/2048/4096 (optional), 4 bytes per channel |
Resolution | ≤3.5% (1.5 inch bismuth bromide probe) |
Power consumption | typical 1.5W |
Weight | 550 g |
Operating temperature | -20 ° C ~ 55 ° C (optional -40 ° C ~ 85 ° C) |
Dimensions | Φ62.5mm χ 80 mm (very small, full grip) |
Storage | with energy spectrum storage |
Alarm | high count buzzer alarm |
Timing measurement | 1 ~ 65535 seconds can be set (hardware level, accuracy 8ns) |
Storage temperature | -40 ° C ~ 85 ° C |
Stable spectrum interface | high voltage stability spectrum (accuracy 0.02V), temperature stability spectrum (accuracy 0.08 °C) |
Communication | USB (providing driver) |
Expandability | Provide B3 board position, defined by customers (such as nuclide identification, stabilization, communication protocol conversion, etc.) |
Stable spectrum range | -55 ° C ~ 125 ° C (accuracy 0.08 ° C) |
MCA-X Dimension
MCA-X Connector
Advantage:
1.Portable
2.Low cost
Application:
1.Handheld nuclide identifier
2.Iodine 131 measuring device
3.Portal radioactive contamination test
4.Airborne gamma measurement
5.Nuclear power plant radiation monitoring
6.University research equipment
7.Nuclear power plant F18 measuring device
8.Anti-Campton anti-cosm ray energy spectrum measurement
9.Neutron spectrometer
10.α spectrometer
11.4G mobile radiation monitoring station
12.CZT spectrometer
Product shots:
FAQ:
1.Q: Are you a factory manufacturer?
A: Yes ,we are manufacturer with 13 years experience in the scintillator crystal industry and supplied many famous brands with good quality and service.
2.Q:Where is your main market?
A:Europe, America, Asia.