Home ProductsScintillator Detector

LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate

Certification
China Kinheng Crystal Material (Shanghai) Co., Ltd. certification
I'm Online Chat Now

LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate

LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate
LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate

Large Image :  LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate

Product Details:
Place of Origin: China
Brand Name: Kinheng
Certification: ISO
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: Negotiable
Packaging Details: foam box
Delivery Time: 4-6 weeks
Payment Terms: T/T, Paypal
Supply Ability: 10000pcs/year

LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate

Description
Temperature: -30-70°C Encapsulation: Aluminum Housing
Product Name: LaBr3 Scintillator Detector Warranty: One Year
Advantage: Good Energy Resolution,high Counting Rate FWHM: 3%
Application: Energy Spectrometer Dimension: 1"x1";1.5"x1.5";2"x2"
High Light:

1.5"x1.5" Scintillator Detector

,

2"x2" LaBr3 Detector

,

1"x1" Scintillator Detector

Good energy resolution high counting rate LaBr3 Scintillator Detector

 

Model LaBr3(Ce) Scintillation Detector is a medium-resolution scintillation detector featuring a 1.5 x 1.5 in. LaBr3(Ce) crystal in a hermetically sealed aluminum housing, including a photomultiplier tube, an internal magnetic/light shield, and a 14-pin connector.The LaBr3(Ce) detector is completely compatible with the signal processing electronics normally used with NaI(Tl) scintillation detectors. However, the performance of the LaBr3(Ce) device is superior to that of NaI(Tl) detectors.

Properties:

 

Specification Range Unit
Scintillator Effective Size φ38 X 38 mm
Input Voltage 11.5 ~12.5 V
Input Current ≤60 mA
Output Polarity Positive Polarity -
Output Amplitude (MAX)1) 9 V
Output Amplitude(TYPE)2) 1 V
Resolution(Cs137)3) ≤3.5 %
<span color:black;background:white;"="" style="font-size: 1pt;"> Background Count Rate(30kev~3Mkev) ≤250 min-1
Work Temperature 0℃ ~ +40
Storage Temperature -20 ~ 55
Humidity ≤90 %

Notes:
1.Detector signal exceeds this value, a truncation will occur.
2.The amplitude of signal is usually less than 1V in spectrum analysis.
3.The value is measured when detector preheated for 10 minutes, the counting rate within 1000, total counting number is less than 105 in Cs137 peak.

 

Advantage:

Good energy resolution

High light output

High counting rate

FWHM 3%

 

Product shots:

LaBr3 Scintillator Detector Good Energy Resolution High Counting Rate 0

 

FAQ:

1.Q: Are you a factory manufacturer?

A: Yes ,we are manufacturer with 13 years experience in the scintillator crystal industry and supplied many famous brands with good quality and service.

 

2.Q:Where is your main market?

A:Europe, America, Asia.

 

Contact Details
Kinheng Crystal Material (Shanghai) Co., Ltd.

Contact Person: Ivan. wang

Tel: 18964119345

Send your inquiry directly to us (0 / 3000)