Good energy resolution with stability PMT CsI(Tl) scintillator detector
Introduction
KHD-1 scintillation detector is a new generation γ-ray measurement device. Combined with lead chamber and Digital Multi-channel Analyzer(DMCA) to form Energy Spectrometer, widely used in weak radioactivity analysis field, such as building materials, food, geology etc.
KHD-1 scintillation detector's advantage including compact structure,easy operation,low background,excellent energy resolution,stable output,high reliability,durability and high detection efficiency.
CsI(Tl) has very good stopping power, is slightly hygroscopic and with good plastic mechanical properties. Combined with a relatively good radiation hardness properties, CsI(Tl) is also well suited for High Energy Physics. It is used in Phoswiches for whole body counting and X-ray astronomy as the "guard crystal" with typically a thin NaI(Tl) as the primary detector. Depending on growth conditions CsI(Tl) crystals can be obtained with low afterglow for application in tomographic systems.
Properties
Specification | Range | Unit |
Scintillator Effective Size | φ50 X 50 | mm |
Input Voltage | 11.5 ~12.5 | V |
Input Current | ≤60 | mA |
Output Polarity | Positive Polarity | - |
Output Amplitude (MAX)1) | 9 | V |
Output Amplitude(TYPE)2) | 1 | V |
Resolution(Cs137)3) | ≤7.5 | % |
<span color:black;background:white;"="" style="font-size: 1pt;"> Background Count Rate(30kev~3Mkev) | ≤250 | min-1 |
Work Temperature | 0℃ ~ +40 | ℃ |
Storage Temperature | -20 ~ 55 | ℃ |
Humidity | ≤90 | % |
Notes:
1.Detector signal exceeds this value, a truncation will occur.
2.The amplitude of signal is usually less than 1V in spectrum analysis.
3.The value is measured when detector preheated for 10 minutes, the counting rate within 1000, total counting number is less than 105 in Cs137 peak.
Advantage:
Good energy resolution
Low cost
Stability
Application:
Medical X-ray Computer Tomographs (CT)
Environmental monitoring: gamma-radiation monitoring
Security control: active potral monitors, X-ray scaning systems, radiation isotope identification devices
Industrial –health physics, neutron activation analysis, non-destructive testing (defectoscopy)
High Energy Physics (HEP) and Electromagnetic calorimeter of Astrophysics
Position sensitivity detectors