Product Details:
|
Applicable PMT: | 2” OR Above | Scintillator Detector: | NaI(Tl)/ LaBr3 |
---|---|---|---|
Humidity: | ≤70% | Model: | MCA-1024 |
Communication: | TTL | Max Channel: | 1024 |
Power Protection: | NOT | Communication Rate: | 1.4W |
Expansion Board: | Yes | ||
High Light: | Handheld Multi Channel Analyser,Handheld electronic test equipment,Multi Channel Analyser MCA-1024 |
Handheld nuclide identifier Digital Multi Channel Analyser(MCA-1024)
Radiation caused by radiation sources due to ionization in the form of alpha, beta, gamma, X-ray and neutron radiations is harmful to human health. Multi-Channel Analyzers (MCAs) are incorporated in nuclear instruments for various applications like Isotope identifiers, Alpha/Gamma spectroscopy and liquid scintillators etc., that demand wide resolutions. Analog signal which is detected by the detector from radiation source is converted into digital using Analog-to-Digital Converter (ADC).
Properties:
Model Parameter |
MCA-1024 | MCA-2048 | MCA-X |
Applicable PMT | 2” OR Above | 2” OR Above | 2” OR Above |
PMT model No. | CR173 CR160 CR119 XP3330 S600-8532 R1307 | ||
Storage temperature | -40 ~ 70℃ | -40 ~ 70℃ | -40 ~ 70℃ |
Applicable temperature | -20~ 55℃ | ||
HV supply | 0~+1250V | ||
Scintillator Detector |
NaI(Tl)/ LaBr3 | ||
Humidity | ≤70% | ||
Power Supply | 5V | 5V | 5V 12V 19V 24V |
Spectrum stabilization | Applicable | ||
Communication | TTL | USB | 485 |
Max Channel | 1024 | 2048 | 32768 |
Power Protection | NOT | Anti static protection |
Static Overvoltage Overcurrent Thunderstrike |
Communication rate | 115200 | 460800 | 460800 |
Power dissipation | 1.4W | 1.8W | 3.5W |
Expansion board | Yes | No | No |
Property | Parameter |
Pulse pass rate | ≥ 1 million cps |
Number of channels | 1024/2048/4096 (optional), 4 bytes per channel |
Resolution | ≤3.5% (1.5 inch bismuth bromide probe) |
Power consumption | typical 1.5W |
Weight | 550 g |
Operating temperature | -20 ° C ~ 55 ° C (optional -40 ° C ~ 85 ° C) |
Dimensions | Φ62.5mm χ 80 mm (very small, full grip) |
Storage | with energy spectrum storage |
Alarm | high count buzzer alarm |
Timing measurement | 1 ~ 65535 seconds can be set (hardware level, accuracy 8ns) |
Storage temperature | -40 ° C ~ 85 ° C |
Stable spectrum interface |
high voltage stability spectrum (accuracy 0.02V), temperature stability spectrum (accuracy 0.08 °C) |
Communication | USB (providing driver) |
Expandability |
Provide B3 board position, defined by customers (such as nuclide identification, stabilization, communication protocol conversion, etc.) |
Stable spectrum range | -55 ° C ~ 125 ° C (accuracy 0.08 ° C) |
MCA-1024 Dimension
Advantage:
1.Portable
2.Low cost
Application:
1.Handheld nuclide identifier
2.Iodine 131 measuring device
3.Portal radioactive contamination test
4.Airborne gamma measurement
5.Nuclear power plant radiation monitoring
6.University research equipment
7.Nuclear power plant F18 measuring device
8.Anti-Campton anti-cosm ray energy spectrum measurement
9.Neutron spectrometer
10.α spectrometer
11.4G mobile radiation monitoring station
12.CZT spectrometer
Product shots:
FAQ:
1.Q: Are you a factory manufacturer?
A: Yes ,we are manufacturer with 13 years experience in the scintillator crystal industry and supplied many famous brands with good quality and service.
2.Q:Where is your main market?
A:Europe, America, Asia.
Contact Person: Ivan. wang
Tel: 18964119345